Manual Indicador K3
test company, Jaime Pla


.



4. INITIAL RESET TO ZERO When switching on the unit, it will automatically set to zero. This will be indicated in the display with the message -00-. Automatically resetting to zero at the start requires the scale to remain stable for at least 5 seconds. For as long as the scale is moving, the -00- indication will be maintained for a maximum of 10 seconds. If this time period is exceeded without obtaining a stable reading, the display will show an Err 0 message followed by the weight on the scale. If the weight on the load receptor is higher than 10% of the scale’s maximum capacity, the error message Err 0 will be displayed, followed by the weight on the scale. The InI-0 option in the configuration menu activates or deactivates the initial zeroing.